Is there power in and out of timer?  Yes / No











Is manifold pressure at manufacturer’s recommended setting?  Yes / No











Do solenoids and diaphragms operate properly?  / No











Is pulse duration at recommended setting? (0.1 - .015 sec)  Yes /











Is cleaning interval at the lowest setting that will allow air manifold pressure to rebuild?  Yes / No











Is differential pressure reduced by stopping fan while pulsing?  Yes / No











Turn on power and/or repair timer.











Check for leaking solenoids and pulse valves; check compressed air source and check differential pressure.











Repair solenoid of diaphragm and check differential pressure.











Change setting and check differential pressure.











Change setting and check differential pressure.











Did you pull a filter bag and run a permeability test to check for blinding?  Yes











Is filter bag blinding?   Yes / No











Analyze for cause of blinding and correct; Replace filters and check differential pressure.











Is air/cloth ratio less than 6:1 if pulse-jet, 4:1 if Plenum Pulse, or 3:1 if reverse air or shaker?   Yes /











Is material being continuously removed from hopper?  Yes / No











Contact BPS for further recommendations.











If pulse-jet or plenum pulse, consider pleated media conversion. If reverse air or shaker, consider pulse-jet conversion or increasing collector size.











Remove material continuously and check differential pressure.










































Decorative Separator Call 800 584 4720 To Speak With A Knowledgable And Experienced Account Rep or email info@GlobalConstruction.com
Copyright © 2007 GlobalConstruction.com All Rights Reserved                                                                                                        Today is 2008-09-06 Arabic     |   Chinese   |   French      |    German   |   Italian     |   Japanese   |   Korean   |   Portuguese   |   Russian            |   Spanish
ArabicTranslation.gif        ChineseTranslation.gif               Francais        Deutsch      Italiano      JapaneseTranslation.gif             KoreanTranslation.gif         Portuguese       RussianTranslation.gif       SpanishTranslation.gif     
ArabicTranslation.gif              ChineseTranslation.gif                FrenchTranslation.gif                 GermanTranslation.gif                ItalianTranslation.gif            JapaneseTranslation.gif                   KoreanTranslation.gif              PortugueseTranslation.gif                      RussianTranslation.gif                         SpanishTranslation.gif